Integrated IT(Isolation Transformer) & UPS Cabinet
ICARELIFE IT-UPS cabinet in medical environments integrates Uninterruptible Power Supply (UPS) with Isolation Transformers (IT) to ensure a stable, uninterrupted, and electrically isolated power supply for critical medical equipment.
Features
Dual Functionality:
- Combines UPS and IT isolation systems for seamless integration and simplified installation.
- Eliminates the need for separate units, reducing installation space and costs.
Unmatched Reliability:
- Zero transfer time ensures uninterrupted power during emergencies.
- Overload capacity of up to 150% for 10 minutes or 130% for 1 minute.
Comprehensive Safety:
- Real-time insulation resistance monitoring with alarm range: 50-999kΩ.
- Leakage current detection (<50μA) and rapid alarm response (<2 seconds) for enhanced safety.
- Temperature detection from -50°C to +200°C with PT100 sensors.
Customizable Power Options:
- Available in 3KVA, 6KVA, and 10KVA capacities to meet diverse hospital demands.
- Supports up to 8 output circuits, ideal for operating rooms and critical areas.
Intelligent Monitoring:
- Equipped with RS-485 interface and Modbus communication protocol for remote control and monitoring.
- Built-in alarm and event logging system for efficient fault diagnosis and maintenance.
Space-Saving Design:
- Compact dimensions (750x400x1800mm) with wall-mount installation option.
- Fireproof glass panel for safe and transparent operation.
Certified Quality:
- Complies with IEC61326-2-4 and 3C certifications for electromagnetic compatibility and safety.
IT-UPS Cabinet Specs (10Kva )

UPS Power Supply:
- Equipped with a 10K high-frequency UPS, supporting 16 free-maintenance 26AH batteries (10KVA) integrated into the cabinet. Backup time: 30 minutes.
- The UPS integrated monitoring unit enables real-time data transmission.
- The UPS features bypass and maintenance functionalities.
Isolation Power System:
- Single isolation transformer (8KVA) with insulation monitoring, transformer temperature monitoring, and load monitoring integrated into the cabinet.
Cabinet:
- Made of flameproof glass and sprayed steel material.
- Aluminum alloy cabinet framework.
- Internal cooling equipment with side heat dissipation.
- Equipped with smoke and over-temperature alarm devices inside.
- High-degree modular design with logical partitioning.
- Cabinet dimensions: 750mm (W) x 1800mm (H) x 400mm (D).
IT-UPS Cabinet Config (10Kva )

No. | Name | Specification | Qty |
---|---|---|---|
1
|
Load Isolation Switch
|
Interpact INS80
|
1
|
2
|
Circuit Breaker
|
IC65N 4P C20A
|
1
|
3
|
Surge Protector
|
IPR20 20KA 3P+N
|
1
|
4
|
Combiner Box
|
RT18-32/6
|
1
|
5
|
Medical Intelligent Insulation Monitor
|
AIM-M100
|
1
|
6
|
Medical DC Power Supply
|
HDR-60-24
|
1
|
7
|
Leakage Circuit Protector
|
IC65N 4P C20A vigi A 30mA ELM
|
1
|
8
|
Leakage Circuit Protector
|
IC65N 4P C16A vigi A 30mA ELM
|
3
|
9
|
Circuit Breaker
|
IC65N 10A 1P
|
5
|
10
|
Circuit Breaker
|
IC65N 2P 50A
|
2
|
11
|
Circuit Breaker
|
IC65L MA 2P 25A
|
8
|
12
|
Isolation Transformer
|
AITR1000S
|
1
|
13
|
Cooling Fan
|
KA1238HA2BAT
|
1
|
14
|
Control Panel
|
7-inch LCD
|
1
|
15
|
Medical Battery
|
26AH Lead-Acid Battery 12V
|
16
|
FAQ
What is Integrated IT & UPS cabinet ?
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Why need an Isolation Transformer in a UPS?
In UPS systems, isolation transformers provide galvanic separation between the input and output, enhancing safety, reducing noise, and improving power quality by mitigating surges and ground loops.
- Safety:Isolation transformers prevent electric shock by ensuring there's no direct electrical path between the power source and the device.
- Power Quality:They reduce electrical noise and disturbances, ensuring that sensitive equipment receives clean and stable power.
- Grounding:They can help resolve grounding or voltage compatibility issues and eliminate ground loops.
- Surge Protection:They protect against voltage spikes and surges, safeguarding connected equipment.
- Harmonic Reduction:They can limit harmonics, which are unwanted frequencies in the power supply that can cause problems for sensitive equipment.
- Voltage Conversion:They can step up or step down voltage, making them useful when the UPS output voltage is different from the load's requirements.
- DC Component IsolationIn transformer-based UPS systems, the transformer not only steps up the inverter output voltage, but also isolates DC components and therefore the DC circuit from the output load