Table of Contents
    Add a header to begin generating the table of contents
    Scroll to Top
    Laminar air ceiling

    Laminar airflow ceiling

    ICARELIFE provides advanced laminar flow ceilings for cleanroom use in operating rooms, ensuring contamination-free environments through efficient air filtration and uniform airflow. Key features include multiple filtration levels, durable construction, and customizable designs to suit various client needs.

    Laminar air flow ceiling

    High-Efficiency Filtration

    Equipped with H14 HEPA filters to deliver ultra-clean airflow and minimize contamination risks.

    Uniform Air Distribution

    200-mesh diffusion net ensures consistent, turbulence-free airflow across the surgical zone.

    Customizable Sizing

    Available in multiple dimensions (2600×1400mm to 2600×2400mm) to suit various cleanroom layouts.

    Durable & Corrosion-Resistant

    Constructed from 1.2mm powder-coated electrolytic steel for long-term reliability.

    Integrated & Space-Saving Design

    Combines lighting, filters, and diffusers into one streamlined, efficient ceiling unit.

    ISO 7 Laminar Airflow Ceiling
    ISO 6 Laminar Airflow Ceiling
    ISO 5 Laminar Airflow Ceiling
    CATETORYDETAIL
    Dimensions
    - Standard Sizes: 2600 × 2400 × 500 mm / 2600 × 1800 × 500 mm / 2600 × 1400 × 500 mm
    - Opening Sizes: 2606 × 2406 × 500 mm / 2606 × 1806 × 500 mm / 2606 × 1406 × 500 mm
    Material
    - 1.2 mm thick electrolytic steel plate with white powder coating for corrosion resistance
    - 200-mesh stainless steel diffusion screen
    Air Filtration
    - H14 HEPA filters with 99.995% efficiency
    - Filter Options:  • 610 × 305 × 292 mm (8 units)  • 366 × 946 × 69 mm  • 676 × 1196 × 69 mm
    Airflow Distribution
    Uniform airflow design with laminar diffusion, ensuring ISO Class 5 cleanliness levels
    Sealing & Airtightness
    - Fully welded assembly to ensure leak-free performance
    - Seamless integration with ceiling structures for optimal airtightness
    Noise Levels
    ≤ 42 dB during operation
    Installation Type
    Modular design with hanging or interlocking system for quick assembly and alignment
    Customization Options
    - Sizes: Custom dimensions available upon request
    - Finish: White powder-coated surface or other finishes as per client requirements
    Durability
    - Load-bearing capacity for maintenance access (walkable ceiling panels)
    - High-strength welded construction for longevity
    Certifications
    - Compliant with ISO 14644 Cleanroom Standards
    - H14 HEPA Filter Certification
    - National-level fire rating (Grade A Certification)
    Integration Features
    - Compatible with ICARELIFE HVAC systems for seamless air handling
    - Lighting systems integration available
    Maintenance Acces
    - Easy-to-remove panels with spring-loaded clips
    - Tool-free access to filters for simplified replacement
    Application
    Operating rooms, cleanrooms, ICUs, laboratories, and pharmaceutical environments

    Laminar AC & Disinfection Ceiling​

    Laminar AC and Disinfection Ceiling System

    ICARELIFE’s Compact Ceiling AC & Disinfection System offers an integrated solution for small to mid-sized facilities, combining air conditioning with disinfection. It lowers installation and maintenance costs compared to traditional systems. Although it has moderate airflow and lacks humidity control, its energy efficiency and ease of use make it ideal for ensuring clean, comfortable air in critical environments.

    Laminar AC and Disinfeciton Ceiling
    FeatureICARELIFE Laminar AC & Disinfection CeilingConventional Laminar Airflow Ceiling with AHU
    Design
    Compact, integrated unit
    Requires AHU and ducting
    Functionality
    Air cooling & disinfection only
    Cooling, humidity control, and airflow
    Installation Cost
    Low
    High
    Maintenance Cost
    Low
    High
    Airflow Performance
    Moderate
    High
    Humidity Control
    Not available
    Available
    Energy Efficiency
    Higher due to compact design
    Lower due to large system size
    Application
    Small to mid-sized facilities
    Large hospitals, specialized areas
    Key Selling Point
    Affordable, easy installation, compact
    Comprehensive environmental control

    All-in-One Design

    Integrates cooling and plasma disinfection in a compact, ceiling-mounted unit.

    Energy Efficient

    Reduces energy consumption by up to 40% compared to traditional systems.

    Easy Installation

    No need for AHU; simplified ducting minimizes installation and material costs.

    Durable & Low Maintenance

    Designed for 70,000+ hours of operation with minimal servicing required.

    Laminar AC and Disinfeciton Ceiling
    Laminar AC & Disinfection Ceiling Install Video
    CategorySpecification
    Application
    Standard Operating Room, General Isolation Room, Burn Unit, ICU, Sterile Area
    Design
    Compact ceiling-mounted unit
    Functionality
    Air cooling and disinfection
    Airflow Performance
    Moderate, suitable for maintaining clean air in medium-sized facilities
    Airflow Rate
    800-1500 m³/h
    Cooling Capacity
    7.2 kW
    Heating Capacity
    7.9 kW
    Humidity Control
    Not available
    Noise Level
    ≤ 50 dB(A)
    Power Supply
    220V/1P/50Hz
    Energy Efficiency
    High, optimized for reduced power consumption
    Disinfection Technology
    Plasma-based sterilization with Coulomb force technology
    Disinfection Efficacy
    99.9% kill rate for airborne Staphylococcus; 95.35% reduction in natural bacteria
    Filter Type
    Integrated HEPA filtration
    Installation Requirements
    Direct ceiling installation; no separate AHU or ducting required
    Space Requirement
    Compact design eliminates the need for a separate machine room
    Maintenance
    Minimal; no consumables required
    Operating Lifespan
    Over 70,000 hours
    Compliance Standards
    GB/T 14929.4-2008; Disinfection Technical Specifications (2002 version)
    Product Dimensions
    1500 x 950 x 455 mm
    Weight
    165 kg
    Target Market
    Small to mid-sized hospitals, outpatient clinics, healthcare facilities

    Application

    Standard Operating Room

    Delivery Room, Infant Room

    Premature Infant Room

    General Isolation Room

    Supply Room, Sterile Area

    Burn Unit, Intensive Care Unit

    • Air: ≤ 200 cfu/m³
    • Surface: ≤ 5 cfu/cm²
    • Healthcare Personnel Hands: ≤ 5 cfu/cm²

    Duct-free Laminar Ceiling

    The ICARELIFE Duct-Free Laminar Ceiling delivers clean, controlled airflow with six integrated FFUs, achieving 99.99% filtration efficiency (H14). Its duct-free design reduces costs, simplifies installation, and saves space, making it ideal for operating rooms and sterile environments.

    Duct-free Laminar Ceiling

    Duct-Free Design

    Simplifies installation, lowers costs, and removes the need for traditional ductwork.

    Integrated FFUs

    Includes six high-efficiency FFUs with 99.99% (H14) HEPA filtration for optimal air purity.

    Quiet & Energy-Efficient

    Operates at 48–58 dB with low power consumption (900W–1140W ±5%).

    Adjustable Airflow

    Three-speed control (0.45–0.75 m/s ±5%) adapts to various cleanroom requirements.

    Compact & Durable

    Lightweight aluminum frame offers strength while maximizing ceiling space.

    Duct-Free Laminar Ceiling
    Duct Free Laminar Ceiling
    Duct Free Laminar Ceiling
    Duct Free Laminar Ceiling
    SpecificationDetails
    Product Name
    Duct-Free Laminar Ceiling, ICARELIFE Model
    Filtration Efficiency
    ≥ 99.99% (H14), certified HEPA filters ensuring 100% filtration at 0.3µm
    Airflow Speed
    Adjustable between 0.45-0.75 m/s ±5%
    Noise Level
    ≤ 58 dB, measured at 1.5m below the uni
    Power Consumption
    300W-380W ±5%, operates on 220V, 50Hz
    Material
    Aluminum alloy, lightweight, and durable
    Initial Pressure Drop
    ≤ 125 Pa, ensuring efficient and uniform airflow
    Number of FFUs
    Integrated with 6 high-efficiency Fan Filter Units (FFUs)
    Duct Requirement
    Duct-free design eliminates the need for traditional duct installations
    Vibration Peak
    ≤ 5µm for stable and reliable operation
    Dimensions
    1600mm x 2400mm, compact and modular for easy ceiling integration
    Weight
    Approx. 85 kg, lightweight for simplified installation
    Applications
    Ideal for operating rooms, cleanrooms, and ICUs
    Certification
    CE and ISO certified, meeting safety and quality standards
    Installation
    Ceiling-mounted, duct-free setup for simplified assembly
    Service Life
    ≥ 50,000 hours, designed for long-term, low-maintenance operation
    Temperature Control
    Not included, focuses solely on clean airflow delivery
    Humidity Control
    Not included, optimized for efficient airflow and disinfection

    Contact Us

    ICARELIFE , Your reliable partner in MOT equipment and supplies.

    Ceiling Laminar Airflow

    Contact US

    ICARELIFE are committed to offering  a wide range of  product for OR builder

    Corian Medical Scrub Sink
    ICARELIFE, Solution for OR Builder
    You reliable solution on modular operating room equipment and supplies.

    Contac Us

    Contac us

    Operating Room Hermetic Door