Negative and positive pressure isolation environments — airtight envelopes, interlocked anterooms, HEPA-filtered exhaust, and continuous pressure monitoring — supplied to contractors and EPC teams as one coordinated system. When containment is the specification, the interfaces cannot be left to chance.
An isolation room that reads −15 Pa on the gauge but leaks through an unsealed panel joint, a poorly fitted door, or an uncoordinated service penetration is not an isolation room — it is a liability. Containment performance is a whole-envelope property: walls, doors, anterooms, HVAC, and monitoring must be engineered together and verified together. ICARELIFE supplies that envelope as one system, with one party accountable for the result.
Configured for infectious isolation, protective isolation, or ICU bays — quoted as a line-item bill of quantities for tender or purchase order.
Sealed modular panels with coved trim and gasketed joints — washable, disinfectant-resistant, and engineered for envelope airtightness.
Automatic sliding hermetic doors with anteroom interlock logic — the cascade holds even during patient and staff movement.
Supply and extract design delivering stable cascades, air change rates, and HEPA-filtered exhaust per room classification.
Room-side differential-pressure displays with alarms and BMS output — containment status visible at a glance, continuously.
Gowning anterooms, interlocked pass boxes, and vision panels configured to your infection-control workflow.
Gas outlets, bedhead trunking, isolation power, and nurse-call provisions coordinated on one utility matrix.
A defined process built for hospital construction schedules — with documentation at every gate.
We review your ward layout against cascade design and infection-control workflow.
Shop drawings, cascade schematics, and a line-item bill of quantities.
Production with QC photo reports; third-party inspection welcome at factory.
Room-by-room labelled packing, shipped DDP to site with full customs handling.
Installation guides, remote supervision, and commissioning protocols.
At the height of the pandemic, UNOPS procured ICARELIFE powered air-purifying respirators (PAPR) for frontline health workers in the Philippines — international-agency vetting of our respiratory protection and contamination-control engineering, the same discipline behind every isolation environment we supply.
Read the full story →Documentation packages are prepared to match your project’s referenced standards and local health-authority requirements.
Share your drawings and specification. We respond with a scope confirmation, cascade design notes, and a line-item DDP quotation.