OR Digital Clock with Temperature & Humidity Display
A flush-mount LED panel that puts time, date, room temperature and relative humidity on the operating-room wall in one sealed, cleanable unit.
Swiss Sensirion SHT-series sensing gives ±0.3 °C and ±3% RH at the point of care, and an on-board SD card logs both continuously for commissioning records and environment audits. The 500 × 300 × 55 mm aluminium frame is pre-dimensioned for flush integration into ICARELIFE modular operating-room wall panels.

Product range
OR Digital Clock
One display unit, three mounting options: flush-embedded in an ICARELIFE modular wall panel, surface-mounted on a finished wall, or ceiling-suspended. Custom panel sizes are built to order.

ORC-500FOR Digital Clock · Flush-MountEnvironment display · Recessed in OR wall panels500 × 300 × 55 mmFlush-embedded panel for modular operating-room wall systems. Needs a 500 × 300 mm cutout and at least 60 mm cavity depth.
ORC-500SOR Digital Clock · Surface / Ceiling MountEnvironment display · Surface or suspended500 × 300 × 55 mmSame panel on a surface bracket or ceiling suspension, for refurbishments and theatres where the wall zone is already occupied.Construction & specifications
Four parameters, one sealed wall panel
The unit consolidates time, date, temperature and relative humidity into a single flush panel, so the surgical team reads the room environment from anywhere in the theatre without a separate instrument cluster. An anodised aluminium alloy frame carries a black acrylic front; high-brightness red LED digit segments stay legible under full operating-theatre lighting. Sensing is handled by a factory-calibrated Swiss Sensirion SHT-series element — the same platform trusted in pharmaceutical and semiconductor cleanrooms — and every reading is written continuously to an on-board SD card. Because the panel is pre-dimensioned at 500 × 300 mm, it drops into the same modular operating-room wall system as the control panel and the gas terminal boxes, so there is no separate procurement and no dimensional mismatch on site.
| Specification | Detail |
|---|---|
| Dimensions & build | 500 × 300 × 55 mm (W × H × D); anodised aluminium alloy frame with a black acrylic front panel; high-brightness red LED digit display |
| Temperature & humidity sensing | Swiss Sensirion SHT-series sensor, factory calibrated; temperature −9 °C to +60 °C at ±0.3 °C (25 °C reference); relative humidity 0–100% at ±3% RH (25 °C, 50% RH reference); display unit switchable between °C and °F |
| Display content & logging | Time HH:MM:SS (24 h), date YYYY/MM/DD, temperature and relative humidity shown simultaneously; continuous temperature and humidity logging to an on-board SD card slot |
| Electrical & control | AC 220 V / 50 Hz, ≤80 W; 1.5 m cable exiting the top of the unit; brightness, date/time and units set by push-button or infrared remote control |
Mounting
Three ways to install the same panel
Mounting is selected at order stage, because it changes the cutout detail, the bracket set and the way the cable is brought to the unit.
| Option | Typical application | What to coordinate |
|---|---|---|
| Flush-wall (recessed) | Modular OR wall panel systems; the default for new theatre builds | 500 × 300 mm cutout and at least 60 mm cavity depth; cutout position fixed before panel fabrication |
| Surface-wall | Refurbishment over a finished wall, or where cavity depth is limited | 55 mm projection from the finished surface; cable route to the top of the unit |
| Ceiling-suspended | Theatres where the wall zone is fully occupied by equipment | Suspension bracket and drop height; viewing angle from the operating table |
Applications
Where the panel is specified
Specified on hospital and life-science projects in Southeast Asia, the Middle East, Europe and South America wherever a controlled space needs continuous, staff-visible environment data.
Standards & reference guidelines
What the readings are checked against
The panel displays and logs environment data. The targets themselves are delivered by the HVAC and AHU system — these are the references the readings are normally measured against.
| Reference | Scope | Targets / relevance |
|---|---|---|
| ASHRAE 170 | Ventilation of Health Care Facilities | Operating room temperature 20–24 °C, relative humidity 20–60% RH |
| ISO 14644-1 / -2 | Cleanroom classification & monitoring | Temperature and humidity are monitored parameters; SD card logging supports the records ISO 14644-2 requires |
| HTM 03-01 | UK NHS healthcare ventilation | Operating room temperature 18–25 °C, relative humidity 40–60% RH |
| GMP EU Annex 1 | Manufacture of sterile medicinal products | Documented environmental monitoring in sterile manufacturing and pharmacy compounding; the SD log supports the audit trail |
How to specify
How to specify your OR digital clock
FAQ
Frequently asked questions
No. The standard unit is display-only: it shows current time, date, temperature and relative humidity, but it has no audible or visual out-of-limit alert. Out-of-limit alarms are handled by the building management system or a dedicated environment monitoring system connected to the AHU or room controller. Tell us at enquiry stage if your project needs an alarm-enabled variant and we will price it as a separate line item.
No. It is a display and logging device, not a certified medical measuring instrument. The Sensirion SHT-series element is factory calibrated to ±0.3 °C and ±3% RH and ICARELIFE supplies the calibration reference with the unit, but where a regulatory regime requires traceable calibrated monitoring you still need a certified data logger running in parallel. The SD card log suits internal record-keeping and commissioning documentation, not statutory calibration records.
Usually yes. Flush installation needs a 500 × 300 mm cutout and at least 60 mm of cavity or sub-frame depth behind the finish; where the cavity is too shallow the panel can be surface-mounted instead, projecting 55 mm from the wall. Send us the wall build-up and a photograph of the current installation and we will confirm the fit before you order.
The on-board SD card records temperature and humidity continuously — remove the card or connect it to a PC to read the log. There is no network or BMS output on the standard unit, so if your project needs readings fed into the hospital BMS, the AHU or room-controller sensors are the normal source. We coordinate that interface during design.
Standard lead time is 20–30 working days from order confirmation and deposit for the 500 × 300 mm panel; custom sizes add about 10 working days. There is no fixed minimum order — single units are accepted on a project basis — and batch deliveries can be scheduled against the site programme.
ICARELIFE provides a datasheet, dimensional drawing, installation notes, the Sensirion sensor calibration reference and a technical specification letter on request — the package typically required for government hospital tenders in Southeast Asia, the Middle East and Africa. Request it with your enquiry.
OR Control Panel
Specify the environment display alongside the control panel that shares the same wall zone — medical gas, lighting, intercom and panel controls coordinated into one section.
Request a Specification for Your Theatre
Send the mounting option, panel size and wall build-up for a line-item quotation, dimensional drawing and tender documentation pack.