ICARELIFE · Power, Control & Utilities

S5 Modular UPS System for Healthcare Facilities

True modular, hot-swappable power protection for hospitals, MRI suites and laboratories — scale from 300 to 500 kW without downtime by adding 50 kW modules.

Online double-conversion UPS with 0 ms transfer, N+1 module redundancy, 95.5% online efficiency and 1+1 cabinet parallel operation. Sized to keep MRI, ICU and life-critical loads running through any mains event.

Hot-swappable 50 kW modules 0 ms transfer time 95.5% online efficiency
View configurations →
ICARELIFE S5 modular UPS cabinet, 300 to 500 kW, built from hot-swappable 50 kW modules
Capacity range300 – 500 kW
Power module50 kW, hot-swap 3U
Efficiency95.5% (online mode)
Transfer time0 ms (online double conversion)

Product range

S5 Modular UPS System

Five cabinet sizes built from the same 50 kW power module: S5 420-300 S / 300 / 350 / 400 / 500. Add modules as the facility grows, or parallel two cabinets (1+1) for higher availability — no forklift upgrade required.

S5 modular UPS cabinet range showing 50 kW hot-swappable power modules
S5 420-300 / 350 / 400 / 500S5 Modular UPS SystemTrue modular online UPS, 3-phase850–1065 × 600–1000 × 2000 mm · 490–1020 kgCabinet capacities 300–500 kW built from hot-swappable 50 kW / 3U modules. 0 ms transfer, N+1 redundancy, 95.5% online efficiency, 1+1 cabinet parallel, RS-232/485/USB + optional SNMP.

Construction & specifications

A modular power plant, not a monolithic box

Each S5 cabinet combines hot-swappable 3U power modules, an intelligent monitoring module, an STS transfer module and integral power distribution behind a 10-inch LCD color screen — up to 500 kW in a single 2000 mm cabinet. Online double-conversion topology delivers 0 ms transfer to battery or bypass; a temperature-compensated battery system sized from 200 AH groups carries ~30 minutes at full load. A built-in maintenance bypass keeps the load powered during service, and swapping a module instead of repairing a monolith cuts MTTR dramatically. Full technical detail is available in the S5 data sheet (PDF).

SpecificationDetail
ArchitectureTrue modular: hot-swappable 50 kW / 3U power modules + intelligent monitoring + STS transfer + power distribution; 1+1 cabinet parallel operation design
Electrical performanceOnline double conversion, 0 ms transfer; output 3×380/400/415 VAC ±1% static accuracy, 50/60 Hz ±0.1 Hz; input PF >0.99, THDi <4%; output THD ≤2% (linear) / ≤4% (non-linear); overload 110% 1 hr, 125% 10 min, 150% 1 min, >150% 200 ms; power walk-in
Battery systemAdjustable ±192–240 V DC bus (32–40 × 12 V cells per group), temperature-compensated float/boost charging; 3 × 200 AH groups give ~30 min at 300 kW
Management & safety10" LCD color screen with live power-flow display; RS-232 / RS-485 / USB, SNMP optional; built-in maintenance bypass; IEC/EN 62040-1 (safety) and IEC/EN 62040-2 Category C3 (EMC), CE; <65 dB, 0–40 °C, IP20
Project coordination: The S5 is facility-infrastructure equipment: size it against the protected load schedule (MRI + chiller, imaging, IT), confirm the site input-voltage window (380 V ±25% / 400 V ±20% / 415 V ±15%) and verify the certification set — CE and EN/IEC 62040-1/2 standard, UL 60601-1 path on request — against your local electrical code before specification.

Model comparison

Five cabinet sizes, one 50 kW module

Specification S5 420-300 S S5 420-300 S5 420-350 S5 420-400 S5 420-500
Cabinet capacity300 kW300 kW350 kW400 kW500 kW
Power modules (50 kW, 3U)667810
Cabinet dimensions D×W×H (mm)850×600×20001065×600×20001065×600×20001065×1000×20001065×1000×2000
Net weight490 kg545 kg654 kg932 kg1020 kg
Input / output3×380 / 400 / 415 VAC (3Ph+N), 50/60 Hz auto-detection
ProtectionIP20; 0–40 °C; 0–95% RH non-condensing; altitude <1000 m

MRI compatibility

Clean power for 1.5T and 3T imaging

The S5 300 kW configuration is sized for MRI suites: ≤2% harmonic distortion and ±1% voltage accuracy keep images artifact-free, 0 ms switching and N+1 redundancy prevent scan interruption or quench events, and the 3:1 peak ratio (up to 900 kVA surge) absorbs gradient-coil demand.

BrandCompatible modelsTypical power need
United ImaginguMR Omega (3T), uMR 570 (1.5T)150–300 kVA
Siemens HealthineersMAGNETOM Vida (3T), MAGNETOM Sola (1.5T)100–200 kVA
GE HealthCareSIGNA Premier (3T), SIGNA Hero (1.5T/3T)100–250 kVA
Philips HealthcareIngenia Elition (3T), Ingenia Ambition (1.5T)100–200 kVA
Canon Medical SystemsVantage Galan (3T), Vantage Orian (1.5T)100–200 kVA
Fujifilm HealthcareEchelon Smart Plus (1.5T)50–150 kVA

How to specify

How to specify your S5 modular UPS

Capacity300 / 350 / 400 / 500 kW cabinets from 50 kW modules; size against MRI + chiller and future expansion
Runtime30 min minimum at full load; 3 × 200 AH battery groups (120 cells) reach ~30 min at 300 kW, 35–58+ min at typical loads
RedundancyN+1 or N+X module redundancy; 1+1 cabinet parallel for higher availability; built-in maintenance bypass for service without interruption
Input / output3×380/400/415 VAC (3Ph+N) in and out; input window −20% to +15%, 40–70 Hz auto-detection
MonitoringRS-232 / RS-485 / USB standard, SNMP with web browser optional; integrate with the hospital BMS
ComplianceCE and EN/IEC 62040-1/2 (TÜV equivalent) as standard; low EMI for wide-bore MRI environments

FAQ

Frequently asked questions

A traditional UPS is a monolithic unit sized once, at installation. The S5 is built from hot-swappable 50 kW modules behind a shared frame: capacity, redundancy and runtime all scale by plugging in modules, and a failed module is swapped without powering down the load. That is what "true modular" means in practice.

The S5 range starts at a 300 kW cabinet, so it is specified for theatre blocks, imaging suites, ICU wings and whole-department loads rather than single rooms or small clinics. Within that range the cabinet is populated with only the 50 kW modules the present load requires, and further modules are added as imaging or IT load grows — so a phase-one department does not pay for phase-three capacity. For loads below 300 kW, ask us to size a room-level solution instead.

Routine checks run through the intelligent monitoring module; power modules, STS modules and batteries are all hot-swappable, so service never interrupts the protected load. A built-in maintenance bypass lets engineers isolate the UPS entirely while the load stays powered, and swapping a module rather than repairing a monolith keeps mean time to repair low. ICARELIFE offers support plans aligned with healthcare compliance and hygiene standards.

Standard warranty is 2 years, extendable to 5. Support includes 24/7 technical assistance, on-site servicing and staff training — worth confirming the response-time commitment for your site when ordering.

Yes. RS-232, RS-485 and USB are standard with optional SNMP (manager and web browser), so the S5 reports into the hospital BMS alongside the OR control panels. The modular architecture also lets you extend power and runtime on the existing frame instead of replacing it.

Request an S5 Sizing Proposal

Send the protected load list (MRI, chiller, IT), required runtime and site input voltage for a line-item S5 configuration and battery sizing.

Or contact us directly: info@icarelife.com · WhatsApp · +86 135 7086 7738

Document revision 2026-09

Contact Us

ICARELIFE , Your reliable partner in MOT equipment and supplies.

Ceiling Laminar Airflow

Contact US

ICARELIFE are committed to offering  a wide range of  product for OR builder

Corian Medical Scrub Sink
ICARELIFE, Solution for OR Builder
You reliable solution on modular operating room equipment and supplies.

Contac Us

Contac us

Operating Room Hermetic Door